General |
|
| Dimensions | master: 338 mm x 333 mm x 154 mm | slave: 175 mm x 154 mm x 246 mm |
| Total weight | master: 5.4 kg | slave: 2.7 kg |
| Protection class | IP 67 |
| Power supply | 6… 30 V |
| Power consumption at 12V | standby approx. 1mA; active operation approx. 140mA |
| operating temperature | – 35… 60°C |
| Miscellaneous | over voltage protection, reverse power protection, lightning protection |
Waterlevel measurement |
|
| Measuring range | 0… 15 m standard version / 0… 35 m extended version |
| Resolution | 1 mm |
| Radar frequency | 26 GHz (K-Band) |
| Radar opening angle | 10° |
Velocity measurement |
|
| Measuring range | 0.08… 16 m/s (depending on flow conditions) |
| Accuracy | +/- 0.01 m/s; +/- 1 % FS |
| Resolution | 1 mm/s |
| Direction recognition | +/- |
| Measuring duration | 5… 240 sec. |
| Measuring interval | 8 sec…. 5h |
| Measuring frequency | 24 GHz (K-Band) |
| Radar opening anlge | 12° |
| Distance to water surface | 0.50… 35 m |
| Minimum swell needed | 3 mm |
Automatic vertical angle compensation |
|
| Accuracy | +/- 1° |
| Resolution | +/- 0.1° |
Interface |
|
| Interface | 1x SDI-12 1 x RS 485 or Modbus |
| Transfer rate | 1.2 to 115.2 kBd |
| Protocol | diverse ASCII-protocols |
| Output | discharge rate, flow velocity, waterlevel, quality parameters |
Discharge measurement for wide rivers with inhomogeneous distribution of flow velocity
With the system of one master-radar sensor and several slave-radar sensors the velocity is measured at several spots throughout the whole water cross-section. Therefore a very high accuracy of the discharge measurement is achieved also for very wide water bodies.
Measuring principle
For the RQ-30d (in comparison to the RQ-30) the measuring principle was enhanced: Here the river is split into multiple sections and from each one a partial velocity measurement is taken. One sensor, the master device, additionally measures the water level and distributes this information to all the other devices (= slaves) in the system. Now they are able to calculate the partial dicharge rate per section. Summing up all partial amounts of discharge results in the total discharge at the actual site – continuously, with non-contact to the water and with increased accuracy. The RQ-30d system can be operated with up to seven slave devices at the maximum.
You are currently viewing a placeholder content from YouTube. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More InformationThe main advantage of the RQ-30d is that the discharge can be measured more precisely, especially in rivers and streams where the flow velocity is distributed inhomogeneously over the cross-section. Varying velocities can be observed particularly in very broad streams as well as in situations, where the measuring site is located close to a river bend, an incoming river or watergates. In order to capture the complete flow-profile even more accurately, the RQ-30d system measures multiple individual flow velocities dispersed over the width of the body of water.
“HailSens represents the culmination of years of dedicated research. As the only hail sensor that seamlessly integrates with hailpad data – the gold standard for scientists worldwide.”
“HyQuant Edge is the first radar sensor-based monitoring station for hydrology built on this architecture. Add a SIM card and power, and go from unboxing to live data in minutes.”
“Both Classic and Edge sensors have their place in modern monitoring. The goal isn’t to eliminate choice — it’s to expand it.”
Fill out the form and our experts will get back to you shortly.

Countrys
Organizations
Certified
You are currently viewing a placeholder content from YouTube. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More InformationYou need to load content from reCAPTCHA to submit the form. Please note that doing so will share data with third-party providers.
More InformationYou need to load content from reCAPTCHA to submit the form. Please note that doing so will share data with third-party providers.
More InformationYou need to load content from reCAPTCHA to submit the form. Please note that doing so will share data with third-party providers.
More Information