| Variants | ||||
| MP500 | MP650 | AR200 | ||
| Measures | Measures | Measures | ||
|
|
|
||
| H 12.13 x D 6.3 inch (H 308 x D 160 mm) 3.09 lbs (1.4 kg) 23 mA @ 12 VDC * |
H 13.11 x D 6.3 inch (H 333 x D 160 mm) 3.09 lbs (1.4 kg) 27 mA @ 12 VDC * |
H 7.64 x D 6.3 inch (H 194 x D 160 mm) 2.43 lbs (1.1 kg) 20 mA @ 12 VDC * |
||
Technical Specifications |
|
| IP Class | IP66 |
| Interfaces | SDI-12 (default) / RS 485 |
| Protocols | SDI-12 V 1.3 (default) / RS 485 (MODBUS-RTU, ASCII, NMEA 0183) |
| Operating Voltage | 10 to 30 VDC for all measuring parameters (opt. heater: 1 A@24 VDC or 24 Watt for wind speed and direction transducers) |
| Connector and Cable | Connector M12-8pol; Cable PUR 32.8 ft (10 m) (other lengths on request) |
| Operating Temperature and Humidity | -40 to 158 °F (-40 °C to +70 °C); 5 % to 100 % RH |
| Operating Measuring and Deployment Range | -40 to 158 °F (-40 °C to +70 °C) (without snow accumulation and/or ice accretion) |
| Operating Measuring Range for Rain | 32 °F to 158 °F (0 °C to +70 °C) |
| Temperature Control Range for Wind Speed and Direction | 14 °F to 39 °F (-10 °C to +4 °C) |
Parameters |
|||||||
| Wind Speed | Wind Direction | Temperature | Relative Humidity | Air Pressure | Solar Radiation | ||
| Principle | Ultrasonic | Ultrasonic | Diode voltage | Capacitive | Piezoresistor | Photoelectric | |
| Range | 0 to 134 mph or 167 mph (0 to 60 m/s or 75 m/s) |
0 to 359.9° | -40 to 176 °F (-40 to +80 °C) |
0 to 100 % RH | 500 to 1100 hPa | 300 to 2100 nm; 0 to 2000 W/m² |
|
| Accuracy | ±0.67 mph (±0.3 m/s) or 3 % |
±3° | ±0.54 °F (±0.3 °C **) MP300: ±0.9 °F (±0.5 °C) |
±3 % RH MP300: ±0.5 hPa |
±0.3 hPa | ±5 % | |
| Resolution | 0.22 mph (0.1 m/s) | 0.1° | 0.18 °F (0.1 °C) | 0.1 % RH | 0.1 hPa | 0.1 W/m² | |
| Additional Device | – | – | – | – | – | MPS100:
H6,3 x D3,94 inch |
|
| * Please note: With interface RS 485 the power consumption is 20 to 30 % less. Please ask for details. ** Accuracy in measuring range 32 to 104 °F (0 to 40 °C): ±32,4 °F (±0.2 °C) |
|||||||
The MP Series compact weather sensors are designed for robust and maintenance-free measurements in hydrology, meteorology and weather-critical applications where durability, precision and operations in different climatic conditions are required.
The compact devices allow for single or all-in-one measurements of up to 6 parameters such as:
All sensors have been tested and approved against following environment conditions:
You are currently viewing a placeholder content from YouTube. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More InformationWeatherSens MP is especially suitable for hydro-meteorological applications by one sensor design and construction, e.g. for
“HailSens represents the culmination of years of dedicated research. As the only hail sensor that seamlessly integrates with hailpad data – the gold standard for scientists worldwide.”
“HyQuant Edge is the first radar sensor-based monitoring station for hydrology built on this architecture. Add a SIM card and power, and go from unboxing to live data in minutes.”
“Both Classic and Edge sensors have their place in modern monitoring. The goal isn’t to eliminate choice — it’s to expand it.”
Fill out the form and our experts will get back to you shortly.

Countrys
Organizations
Certified
You are currently viewing a placeholder content from YouTube. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More InformationYou need to load content from reCAPTCHA to submit the form. Please note that doing so will share data with third-party providers.
More InformationYou need to load content from reCAPTCHA to submit the form. Please note that doing so will share data with third-party providers.
More InformationYou need to load content from reCAPTCHA to submit the form. Please note that doing so will share data with third-party providers.
More Information